Settings
2 options – LHPConf for JSP devices with LHP communication or HARTConf for devices with both HART and LHP communication
• Thermoelectric sensors • Temperature ranges: -200 to +1300 °C • Accuracy classes 1 and 2 • Without fittings (bare stem)
• Complete and efficient assembly for temperature and pressure reduction of measured medium samples
• Measuring resistance: 1x/2x Pt100/1000 • Measuring range: -50 to +150 °C • Wall mount
• Resistance sensor • Temperature range: -40 to +180 °C • Accuracy classes A, B • Integrated PN63 thermowell
• Measuring resistor: 1x/2x Pt100 • Measuring range: -200 to +180 °C • Threaded or bare-stem versions
• Measuring resistor: 1x / 2x Pt100 / Pt1000 / Ni1000 • Measuring range: -50 to +180 °C • Bare-stem design
• Measuring resistor 1x Pt100, Pt1000 • Measuring range -50 to +105 °C • Version with bare stem
• Measuring resistor 1x Pt100 / Pt1000 / Ni1000 • Measuring range -50 to +200 °C • Version with MA connector or MA head
• Resistance sensors • Accuracy classes A, B • Cold junction ending with MA-type head with optional process thread
• 1x / 2x measuring resistor / thermocouple • measuring range: -50 to +400 °C • spring-loaded measuring stem
• Resistance sensor • Temperature range: -200 to +700 °C • Accuracy class A, B • Without fittings (bare stem)
• Resistance sensors • Temperature ranges: -200 to +700 °C • Accuracy classes A, B • Stainless steel protective tube
• Resistance sensor • Temperature ranges: -200 to +700 °C • Accuracy classes A, B • For use with WellTEMP 70 thermowells
• Resistance sensor • Temperature range: -200 to +600 °C • Accuracy class A, B • Integrated PN63 thermowell
• Resistance sensor • Temperature range: -200 to +600 °C • Accuracy class A, B • Integrated PN100 thermowell
• Resistance sensor • Temperature range: -200 to +700 °C • Accuracy class A, B • For use without a thermowell
• 1x/2x Pr100 resistance thermometer • Measurement range: -50 to +100 °C • Ex protection
• Thermocouple 1x "J", "K" • Measuring range -50 to +800 °C • Screw-adjustable, spring-loaded bayonet lock
• Thermocouple sensors • Temperature ranges: -200 to +1300 °C • Accuracy classes 1 and 2 • Stainless steel protection tube
• Thermocouple sensor • Temperature range: -200 to +1300 °C • Accuracy classes 1, 2 • For use with WellTEMP 70 thermowells
• Thermocouple sensors • Temperature ranges: -200 to +1300 °C • Accuracy classes 1 and 2 • Integrated thermowell PN63
• Thermocouple sensors • Temperature ranges: -200 to +1300 °C • Accuracy classes 1 and 2 • Integrated thermowell PN100
• Thermoelectric sensors • Temperature ranges: -200 to +1300 °C • Accuracy classes A, B • For use without a thermowell
• Thermocouple sensors (wire-type) • Temperature ranges: -40 to +1800 °C • Accuracy classes 1, 2, 3 • Ceramic protection tube, 10 mm diameter • Steel support tube
• Thermocouple sensors (wire-type) • Temperature ranges: -40 to +1800 °C • Accuracy classes 1, 2, 3 • Ceramic protection tube, 15 mm diameter • Steel support tube
• Thermocouple sensors (wire-type) • Temperature ranges: -40 to +1800 °C • Accuracy classes 1, 2, 3 • Ceramic protection tube, 24/26 mm diameter • Steel support tube ...
• Thermocouple sensors (wire-type) • Temperature ranges: 0 to +1800 °C • Accuracy classes 1, 2, 3 • Inner sapphire + outer ceramic protective tube, diameter 24/26 mm • Steel...
• Thermocouple sensors (wire-type) • Temperature ranges: -40 to +1200 °C • Accuracy classes 1, 2 • Steel protection tube, 20 mm diameter
• Thermocouple sensors (wire-type) • Temperature ranges: -40 to +1200 °C • Accuracy classes 1, 2 • Steel protection tube 22 mm diameter
You are on page 2 of 3.